ChinaPeptides Tech developed the technology to manufacture highly monodisperse polystyrene/divinylbenzene media for performance reversed phase chromatography. The polymer reversed phase chromatography media with optimized pore structure provides excellent selectivity, low back pressure, and exceptional batch-to-batch reproducibility. ChinaPeptides Tech can offer the complete lines of polymer based reversed phase chromatography media which are designed for laboratory and process scale purification of proteins, peptides, nucleic acids, antibiotics, and low molecular weight pharmaceuticals.
Figure 1: SEM images of monodisperse polymer microspheres with different sizes
Product performance consistency
ChinaPeptides Tech’s advanced manufacturing facilities and reliable quality control system allow the production of bulk volume and guarantee quality as well as batch-to-batch reproducibility. Every batch is examined to ensure consistent performance including particle size, size distribution and pore size (Figure 3). The rigorous quality control is also reflected in the reproducible separations of multiple tested biomolecules. Figure 4 shows the consistency in the product performance from batch to batch.
List of polymer reversed phase chromatography media
ChinaPeptides Tech provides the complete lines of polymer reversed phase chromatography media based on the ly cross-linked polystyrene/divinylbenzen microspheres. Typical available particle sizes are 3, 5, 10, 15, 20, 30 and 40 µm, with pore sizes of 300, 500, and 800 Å. ChinaPeptides Tech’s polymer reversed phase chromatography media are used for laboratory and process scale purification of proteins, peptides, nucleic acids, antibiotics, and low molecular weight pharmaceuticals.
Table 1: The list of polymer reversed phase chromatography media
Name | Particle size(μm) | Pore size(Å) | Matrix |
QY-3PS | 3 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-5PS | 5 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-10PS | 10 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-15PS | 15 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-20PS | 20 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-25PS | 25 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-30PS | 30 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-40PS | 40 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-50PS | 50 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-60PS | 60 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-100PS | 100 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-200PS | 200 | Non-porous, 100, 300, 500, 800 | PS/DVB |
QY-10PSM | 10 | Non-porous, 100, 300, 500, 800 | Poly DVB/acrylate |
QY-15PSM | 15 | Non-porous, 100, 300, 500, 800 | Poly DVB/acrylate |
QY-20PSM | 20 | Non-porous, 100, 300, 500, 800 | Poly DVB/acrylate |
QY-30PSM | 30 | Non-porous, 100, 300, 500, 800 | Poly DVB/acrylate |
QY-40PSM | 40 | Non-porous, 100, 300, 500, 800 | Poly DVB/acrylate |
QY-50PSM | 50 | Non-porous, 100, 300, 500, 800 | Poly DVB/acrylate |
QY-60PSM | 60 | Non-porous, 100, 300, 500, 800 | Poly DVB/acrylate |
QY-100PSM | 100 | Non-porous, 100, 300, 500, 800 | Poly DVB/acrylate |
QY-200PSM | 200 | Non-porous, 100, 300, 500, 800 | Poly DVB/acrylate |
QY-10PMM | 10 | Non-porous, 100, 300, 500, 800 | Polyacrylate |
QY-15PMM | 15 | Non-porous, 100, 300, 500, 800 | Polyacrylate |
QY-20PMM | 20 | Non-porous, 100, 300, 500, 800 | Polyacrylate |
QY-30PMM | 30 | Non-porous, 100, 300, 500, 800 | Polyacrylate |
QY-40PMM | 40 | Non-porous, 100, 300, 500, 800 | Polyacrylate |
QY-50PMM | 50 | Non-porous, 100, 300, 500, 800 | Polyacrylate |
QY-60PMM | 60 | Non-porous, 100, 300, 500, 800 | Polyacrylate |
QY-100PMM | 100 | Non-porous, 100, 300, 500, 800 | Polyacrylate |
QY-200PMM | 200 | Non-porous, 100, 300, 500, 800 | Polyacrylate |
|